Vulk - FinseaI Invisi WB - Water based penetrating sealer

  • Vulk - FinseaI Invisi WB - Water based penetrating sealer

Water based clear penetrating sealer

Water Based
Penetrating

Available Options

Finseal Invisi WB is a clear impregnating low VOC sealer that is designed to protect concrete, absorbent natural stone and masonry surfaces. Finseal Invisi WB is a water-based formulation containing a fluoro-acrylic modified microemulsion that has good penetration and is fast drying. Treated substrates are UV stable, hydrophobic and resist staining from ingress of, oils, salts, organic matter, food and beverages.

Uses

  • Footpaths and public spaces
  • Untreated masonry pavers and concrete
  • Exposed architectural concrete
  • Coloured, stencilled and screeded concrete
  • Porous natural and artificial stone
  • Alfresco dining areas
  • Driveways and Carparks
  • Pool concourse
  • Natural and artificial stone
  • Masonry paving
  • Decorative concrete overlays
  • Exposed architectural concrete
  • Precast concrete panels

Features And Benefits

  • Significantly reduces water adsorption
  • Significantly reduces oil adsorption
  • Significantly reduces water-borne dirt accumulation
  • Reduction of frost damage
  • Significantly reduces moss, mildew and lichen growth
  • Anti-graffiti properties
  • Does not impart a “wet look” to treated surfaces or contribute to surface gloss
  • Makes general cleaning and removal of chewing gum easier.
  • Does not affect slip resistance of treated surfaces

Estimating Data

Application rate will vary from 1 - 10m²/L depending on the material porosity and application method.
Dense surfaces approx. 5-10m²/L Porous surfaces up to 1-2m²/L
Substrate saturation is essential to achieve maximum result.

 

Curing Time

24-36 hours to full cure at 25ºC. 6 hours of free drying time prior to rain is required.

Surface Preparation

Ensure substrate is clean, dust and stain free prior to application. Clean surface to remove any dirt, laitance, previous coatings or curing agents that may prevent penetration of the material.

The surface must be dry prior to application.

Confirm absorbency of surface with a light water spray, ensuring penetration into the surface is achieved.

It is recommended to undertake a test sample to confirm the suitability of the product for specific substrates and ensure desired results are achieved.

Application Method

Slowly stir the material until thoroughly mixed; Using a low-pressure sprayer fitted with an adjustable spray tip, surface must be flooded at a sufficient rate ensuring to achieve full saturation.

Substrates of greater porosity will benefit from a second application, wet on wet, to ensure penetration is achieved. The properties of the substrate such as porosity and profile will greatly influence the amount of material required.

Tech Data Sheet